    The Neurotrac Obstetric TENS is an obstetric TENS device designed specifically for use during child birth.

    SKU: WEB001656
    *
    *
    Code Type Unit of Measure
    Code: VMOBST Type: Rehab TENS Unit of Measure: EA

    The Neurotrac Obstetric TENS is an obstetric TENS device designed specifically for use during child birth.

    The Neurotrac Obstetric TENS machine is small and light weight and comes with a separate hand held boost button enabling you to easily & quickly select boost mode. When attached you can move around freely during labour.

    • Dual channel Digital Obstetric TENS unit for simple and non-invasive method to decrease pelvic pain when in labour.
    • Dedicated Labour Pain programme for use with Remote Boost switch for additional pain control at times of intense pain.
    • No known side effects for mother or baby
    • Clear bright backlight LCD allows the display to be read more easily in low light or dark conditions.
    • Keypad with bigger buttons for ease of use.
    • Compact, light and reliable

    Specifications

    • Dual channel: individually isolated circuits.
    • Amplitude: 0-90 mA into 500 Ohm load ; indication only. Actual mA will tend to be less than indicated due to electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 70 mA, at 1500 Ohms load the maximum will be limited to 65 mA.
    • Type: Constant Current, maximum output voltage 180 Volts +10 / -30 Volts.
    • Waveform: Asymmetrical, rectangular bi-phasic with zero DC current.
    • Pulse width: 220μS [2% accuracy].
    • Pulse Rate: 90Hz (Continuous mode) [2% accuracy].
    • Mode: Continuous (Boost mode).
    • Burst mode: Bursts of 9 pulses [200 μS] at 150 Hz, repeating twice every second (Rest mode).
    • Ramp up Time: 0.8 seconds from Rest to Boost.
    • Time duration: continuous until switched off.
    • Low Battery Indicator: If the battery goes below 6.9 volts +/- 0.2 volts the battery symbol will flash on/off once every second.
    • If the battery voltage is below 6.6 (+/- 0.2) volts the unit will not turn on.
    • Open Electrode Detect: If an open circuit is detected at the output of channel A or B the output current will be reset at zero.

    Physical dimensions: 108 x 62 x 23 mm.